First Eclipse 500 AD To Limit Flight to VFR Only

AINalerts » June 19, 2007
June 19, 2007, 11:41 AM

The FAA is expected to issue the first Airworthiness Directive on the Eclipse 500 VLJ in the next few days, restricting the jet to day VFR flight because of a pitot/angle-of-attack probe freezing problem that occurred on three flight-test airplanes. Until the AD becomes effective, the Eclipse 500 can be flown IFR but not in IMC, pending installation of a pitot tube fix. The problem took place after takeoff in high-humidity conditions. Moisture inside the pitot tube froze at high altitude, trapping air pressure in the air data computers and shutting down airspeed indications on the primary flight displays, then melting after descent into warmer air. Eclipse has flight tested a new pitot/AOA probe for more than 60 flights and expects certification of the new probe in mid-July. The new tube has a drain in the probe tip, added insulation, new heat-conductive material and a new interior heater. A pitot line drain task will be added to the 300-hour maintenance interval.

FILED UNDER: 
Share this...

Please Register

In order to leave comments you will now need to be a registered user. This change in policy is to protect our site from an increased number of spam comments. Additionally, in the near future you will be able to better manage your AIN subscriptions via this registration system. If you already have an account, click here to log in. Otherwise, click here to register.

 